Ground Pile Pipe

Tianjin Ruide Steel Pipe Manufacturing Co., Ltd.
Ground Pile Pipe,foundation steel pipe,high-strength piling pipe,corrosion-resistant ground pile,ASTM A252 piling pipe
Ground Pile Pipe
Ground Pile Pipe
Ground Pile Pipe
Ground Pile Pipe

Ground Pile Pipe

Ground Pile Pipe: High-Strength Foundation Steel Pipes for Global Construction

Ground Pile Pipe is a critical foundation component engineered to transfer structural loads from superstructures to stable soil or rock layers across Middle East, West Asia, Africa, and Southeast Asia. Designed for superior strength, durability, and adaptability, these steel pipes thrive in regional harsh conditions: Middle East desert sands and extreme heat, West Asian rocky terrain and temperature fluctuations, African tropical wet soils, and Southeast Asian coastal humidity and saline environments. Available in diverse diameters, wall thicknesses, and material grades (carbon steel, high-strength low-alloy steel, weathering steel), they cater to projects of all scales—from high-rise building foundations and bridge piers to marine structures and industrial facilities. With precision fabrication and corrosion-resistant options, they ensure long-term foundation stability and structural integrity for demanding construction needs.

Specification

Item

Details

Product Name

Ground Pile Pipe

Core Dimensions

Diameter: 6" to 120" (DN150 to DN3000+)- Wall Thickness: 6mm to 100mm- Length: 6m to 24m; custom lengths and splicing available

Material Grades

Carbon Structural Steel: ASTM A252 Gr. 2/3, ASTM A500 Gr. B/C, ASTM A572 Gr. 50, EN 10219 S235JRH/S355J0H/J2H- High-Strength Low-Alloy Steel: ASTM A572 Gr. 65, API 5L X70/X80 (marine/offshore use)- Weathering Steel (Corrosive Environments): ASTM A588

Welding Technology

Submerged Arc Welding (SAW) for LSAW/SSAW, High-Frequency Welding (HFW)

Key Mechanical Properties

Yield Strength: 235MPa (EN 10219 S235JRH) to 555MPa (API 5L X80)- Tensile Strength: 360MPa (EN 10219 S235JRH) to 690MPa (API 5L X80)- Load Capacity: Engineered for heavy axial compression and lateral loads

Manufacturing Process

1. Plate/Coil Preparation: 

Cutting, edge preparation, and surface cleaning of high-quality steel plates/coils to meet foundation pipe standards.

2. Forming: 

Precision bending via UOE, JCOE, or spiral forming methods to achieve desired diameter and structural consistency.

3. Welding: 

Primary seam welding using Submerged Arc Welding (SAW) or HFW—ensuring high-strength, defect-free joints critical for load-bearing.

4. Sizing & Straightening: 

Calibration to strict dimensional tolerances for roundness and straightness, enabling smooth driving into diverse soils.

5. Heat Treatment (Optional): 

Normalizing or quenching & tempering to enhance mechanical properties for high-strength and low-temperature applications.

6. Surface Treatment: 

Optional galvanized, painted, or weathering finishes to resist corrosion from soil chemistry and regional climates.

7. Testing & Inspection: 

Hydrostatic testing, ultrasonic testing (UT), radiographic testing (RT), dimensional verification, and Charpy impact tests.

8. Finishing: 

End preparation (pointing, beveling) for easy driving, splicing, and attachment of reinforcement.

Performance & Advantages

Exceptional Load-Bearing Capacity: 

Engineered to withstand heavy axial and lateral loads, ideal for high-rises, bridges, and industrial facilities.

Climate & Corrosion Resistance: 

Weathering steel (ASTM A588) and coated options resist coastal saltwater, tropical humidity, desert erosion, and acidic soils.

Dimensional Stability: 

Precise geometry ensures consistent driving performance and minimal soil displacement during installation.

Fabrication Flexibility: 

Superior weldability enables splicing, end modification, and reinforcement—adapting to custom project needs.

Geological Adaptability: 

Performs reliably in sand, rock, clay, and wet soils across target regions.

Cost-Effective Reliability: 

Durable design minimizes maintenance and replacement costs, suitable for large-scale infrastructure projects.

Standards & Certifications

Our Ground Pile Pipe complies with global and regional foundation engineering standards:

  • Primary Standards: ASTM A252, EN 10219, EN 10210, API 5L (for X70/X80 grades)
  • Structural & Material Standards: ASTM A500, ASTM A572, ISO 630, ISO 3183
  • Corrosion Standards: NACE MR0175/ISO 15156 (sour service), ISO 12944
  • Quality Certifications: ISO 9001, API Q1 (where applicable)
  • Regional Compliance: SASO (Middle East), SONCAP (Africa), SNI (Indonesia), TIS (Thailand), ISIRI (West Asia)
  • All orders include material test certificates (MTC) and inspection reports for project approval.

Quick Selection Table

Application

Recommended Material Grade

Key Specifications

Target Region

High-Rise Building Foundations

ASTM A572 Gr. 50/65, EN 10219 S355J2H

OD 24"-60", WT 15-40mm, high-strength

All Regions

Marine/Coastal Structures

API 5L X70/X80, ASTM A588

OD 36"-120", WT 20-100mm, corrosion-resistant

Southeast Asia, Middle East

Bridge Piers/Highway Supports

ASTM A252 Gr. 3, EN 10219 S355J0H

OD 16"-48", WT 10-30mm, lateral load resistance

West Asia, Africa

Industrial Facility Foundations

ASTM A500 Gr. C, API 5L X65

OD 12"-36", WT 8-25mm, heavy machinery support

All Regions

Slope Stabilization/Land Reclamation

ASTM A588, EN 10219 S235JRH

OD 10"-24", WT 6-15mm, soil adaptability

Africa, Southeast Asia

Regional Customs Document Checklist

Region

Mandatory Documents

Our Support

Middle East (GCC)

SASO Certificate, API 5L Certificate (for X70/X80), Certificate of Origin

Assist with SASO application (3-5 working days)

West Asia (Iran/Iraq)

ISIRI Certificate, Bilingual Test Reports, Import License

Provide Persian/English documents for clearance

Africa (Nigeria/Kenya)

SONCAP Certificate, Form M (Nigeria), MTC & Load Test Reports

Support SONCAP registration and product testing

Southeast Asia (Indonesia/Thailand)

SNI/TIS Certificate, Customs Declaration, Marine Grade Compliance Letter

Coordinate with local agents for smooth clearance

Packaging & Shipping Guidelines

Packaging

  • Pipe ends are capped with plastic to prevent rust, dust, and debris accumulation.
  • Bundled with high-strength steel straps—large-diameter pipes (OD ≥300mm) shipped individually with steel brackets to avoid deformation.
  • Wrapped in moisture-proof film for humid regions (Southeast Asia/Africa) and anti-corrosion paper for deserts (Middle East).
  • Placed on ISPM 15-certified wooden pallets for international shipping compliance.
  • Clear labeling includes product name, grade, dimensions, batch number, and handling instructions.

Shipping

  • Lead Time: Standard orders (≤500 tons): 20-30 working days; Bulk orders (>500 tons): 30-45 working days; Custom-sized piles: 25-35 working days.
  • Logistics Partners: Maersk, CMA CGM, Aramex, and regional heavy-cargo carriers for inland delivery to construction sites.
  • Delivery Coverage: Port-to-port, door-to-door for major cities, and tailored solutions for remote infrastructure projects.

RFQ Frequently Asked Questions & Answers

RFQ Question: Do your ground pile pipes resist desert sand erosion for high-rise foundations?

Answer: Yes, our ASTM A572 Gr. 65 piles (OD 24"-60") withstand desert erosion—with optional epoxy coating for extra protection.


RFQ Question: Need corrosion-resistant piles for coastal port foundations (saltwater exposure)?

Answer: We recommend API 5L X80 marine-grade piles, engineered for saltwater corrosion resistance. They meet NACE MR0175 standards with marine compliance reports.


RFQ Question: Are your piles suitable for rocky terrain bridge piers in temperature-fluctuating regions?

Answer: Our ASTM A252 Gr. 3 piles offer high tensile strength (550MPa) for rocky terrain driving. They adapt to -10°C to 45°C fluctuations with EN 10219 certification.


RFQ Question: Can you supply large diameter (80"+) piles for industrial tank foundations in wet tropical soils?

Answer: Yes, our custom 80"-120" diameter piles (API 5L X70) are designed for wet tropical soils—thick walls (30-80mm) ensure stability.


RFQ Question: What grade of pile pipe is best for seismic-prone construction zones?

Answer: ASTM A572 Gr. 65 high-strength piles offer superior ductility for seismic zones. They absorb lateral forces, meet regional structural codes.


RFQ Question: Do your pipes support splicing for extra-long foundation requirements (over 24m)?

Answer: Yes, our piles are designed for secure welded splicing to reach 30m+ lengths. We use API 5L X70/X80 for consistency, provide splicing guidelines with technical support.